Compex SCSI TO S-ATA RAID Spezifikationen Seite 120

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 258
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 119
Infortrend
4-50
When finished with the configuration, select Execute Drive Testing and
press [ENTER] to proceed.
The Read/Write test progress will be indicated by a status bar.
Figure 4 - 85: Disk Read/Write Testing Completion
Percentage
You may press [ESC] and select "Read/Write Test" later and choose to
"View Read/Write Testing Progress." If you want to stop testing the drive,
select Abort Drive Testing and press [ENTER] to proceed.
Figure 4 - 86: View Read/Write Testing Progress Screen
IMPORTANT!
The disk drive on which a read/write test will be performed cannot
be a spare drive (local or global) or a member of a logical drive.
The "Read/Write Test" option will not appear if the drive is not
indicated as a "New Drive" or a "Used Drive." Also, a drive
formatted with a 256MB reserved space is also excluded from
selection.
Seitenansicht 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 257 258

Kommentare zu diesen Handbüchern

Keine Kommentare